CCT not found


   
How to locate and repair a CCT Fault




LEDs attached to a DR2 do not change color

a) moving the slider while the momentary is pressed does not change color ( it dims)

b) in ZWD, when the device is expanded - the LED Driver mode is not "ALL CCT"




Check LED connections





Visit  Advanced
click on the radio button next to the "short" address of the switch
Click on Query Status
Check that the Left and Right status are OK
If either is "Bad" then there is an open wire to the LEDs - Right is warm, Left is cool.  Repair the wire


Firmware version 54 or later

The number of LEDs on the cool and white string must be the same.   Check this first.
Expand the AL-WS-DR2 switch

on the bottom - there are two status boxes with "height" Left and Right.

Insure that the numbers are the same.     Each P023R6 is 3 units - so if there are 12 in the circuit, then this means there are 4 fixtures of 3 units each.

If the numbers are not the same, then enter the physical number into both sides, Click on Re-Calibrate

 CCT will not be possible until the two sides match

Firmware 53 or earlier

In Advanced, check the button next to the switch number, click on "Reset",turn the switch ON, wait for recaibration

 CCT will not be possible until the two sides match
Test the DR2
Exchange the LED left and right
Click on Reset in Advanced to force a retest see if the "bad' output stays on the same side
Series LEDs not wired right

DL-120
- use lever nuts to bypass all LEDs except one

use the DR2 output to drive one LED, then add one at a time

P023R6
- connect the OJ-606 connectors together - except one


use the DR2 output to drive one LED, then add one at a time



After repairing the wiring fault - click on Rescan device